Product
- Industrial
- Conductivity Meter
- Resistivity Meter
- pH Meter
- Reverse Osmosis Controller
- Flow Meter
- Dissolved Oxygen Meter
- Free chlorine analyzer
- Turbidity Meter
- TSS Meter
- COD
- Fluorion Analyzer
- Sodium Meter
- Silicate Meter
- Hydrazine Analyzer
- Multiparameter analyzer
- Management system
- Transmitter
- Sensor
- Control Panel
- Installation Accessories
- Plastic Electric Box
- water treatment materials
- One-stop Purchase Materials
- Handheld
- Portable Conductivity Meter
- Portable pH meter
- Portable pH and conductivity a
- Portable pH and conductivity m
- Portable pH and dissolved oxyg
- Portable pH ORP conductivity D
- Portable ORP meter
- Portable Dissolved Oxygen mete
- Portable conductivity and DO m
- Portable Free Chlorine meter
- Portable Acid Meter SX7120
- Portable Acid-Alkali Meter SX7
- Portable Hardness Meter YD300
- Portable turbidity meter
- Portable Thermometer
- Portable Tachometer -laser typ
- Portable aquaculture multipara
- Portable COD
- Pentype Conductivity Meter
- Pentype TDS Meter
- Pentype pH meter
- Pentype ORP meter
- Pen type conductivity TDS sali
- Pentype Free Chlorine Meter
- Dual channels TDS Meter for Dr
- Handheld Refractometer
- Laboratory
- Laboratory Conductivity meter
- Laboratory Conductivity Meter
- Laboratory Conductivity and DO
- Laboratory pH meter
- Laboratory pH meter -precise M
- Laboratory pH and Conductivity
- Laboratory pH and Conductivity
- Laboratory pH and DO meter MP5
- Laboratory Dissolved Oxygen me
- Laboratory Turbidity Meter
- Laboratory Fluoride Ion Meter
- Laboratory Sodium Meter
- Laboratory BOD analyzer (diffe
- Laboratory COD Ammonia Nitroge
- Laboratory Calcium Ion Meter M
- Laboratory chroma meter CLR-3
- Laboratory Electrode
- Stirrer
- Accessories
- Aquarium
DCT-8600A
AddTime:2016-12-03 13:42:22 Views: 0

Characteristics
Ø Single point calibration or known concentration calibration under any temperature, convenient and efficient in field application |
Ø Choose manual/automatic measurement of temperature compensation, dissolved oxygen sensor has own temperature measurement |
Ø Three-way OC controller can realize corresponding control of temperature and dissolved oxygen configurately, it can be set as time control |
Ø Two-channel, totally isolated(4~20)mA current loop instrument/transmitting dual mode, dissolved oxygen/ temperature free configuration to send signals |
Ø Manual compensation of pressure and salinity, high speed of measurement, high accuracy, advanced stability |
Ø DC 24V power supply, which conforms to safety specification of high humidity site, internal automatic identification of power port polarity |
Ø Complete design of electromagnetic compatibility, good anti-interference performance, which can achieve safe operation of most electromagnetic environment |
Ø RS485 data communication port, company’s standardized communication protocols |
Ø Limits of authority password protection function, which can prevent non-specialists from login to modify precision parameters optionally |
Technical Parameters
Instrument mode | DCT-8600A Dissolved Oxygen/Temperature Transmitting Controller | |
Matched sensor | DO3135-23Z Dissolved Oxygen Sensor | |
Temperature sensor | Within the Dissolved Oxygen Sensor itself | |
Measurement range | Dissolved Oxygen | (0.0~20.00)mg/L |
Temperature | (0.0~40.0)℃ | |
Resolution | Dissolved Oxygen | 0.01 mg/L |
Temperature | 0.1℃ | |
Stability | Dissolved Oxygen | 0.1 mg/L |
Temperature | 0.2℃ | |
Indication error | Zero error | ±0.10 mg/L |
Dissolved Oxygen | ±0.30 mg/L | |
Temperature | ±0.5℃ | |
Approximate equivalent input impedance | 5×1012Ω | |
Salinity compensation error | Dissolved Oxygen | ±2% |
Compensation range | Temperature compensation | (5~45)℃ |
Working environment | Temperature | (0~50)℃ |
Humidity | ≤85% RH | |
Length of matched cable | ≤30m (5m)general | |
Instrument consumed power | ≤5W | |
Photoelectric switch control output | Three-with isolated photoelectric control output | |
Electric current loop | Two-way can transfer and convert, mutual isolated (4~20)mA electric current loop output Output accuracy: ±0.1mA (loop resistance≤400Ω) |
|
Supply voltage | DC 24V ±4V | |
Protection level | IP65(add back cover) | |
Fixed form | Panel mount rapid stationary type | |
Machine size | 96mm×96mm×94mm (H×W×D) | |
Hole size | 91mm×91mm (H×W) |