Product
- Industrial
- Conductivity Meter
- Resistivity Meter
- pH Meter
- Reverse Osmosis Controller
- Flow Meter
- Dissolved Oxygen Meter
- Free chlorine analyzer
- Turbidity Meter
- TSS Meter
- COD
- Fluorion Analyzer
- Sodium Meter
- Silicate Meter
- Hydrazine Analyzer
- Multiparameter analyzer
- Management system
- Transmitter
- Sensor
- Control Panel
- Installation Accessories
- Plastic Electric Box
- water treatment materials
- One-stop Purchase Materials
- Handheld
- Portable Conductivity Meter
- Portable pH meter
- Portable pH and conductivity a
- Portable pH and conductivity m
- Portable pH and dissolved oxyg
- Portable pH ORP conductivity D
- Portable ORP meter
- Portable Dissolved Oxygen mete
- Portable conductivity and DO m
- Portable Free Chlorine meter
- Portable Acid Meter SX7120
- Portable Acid-Alkali Meter SX7
- Portable Hardness Meter YD300
- Portable turbidity meter
- Portable Thermometer
- Portable Tachometer -laser typ
- Portable aquaculture multipara
- Portable COD
- Pentype Conductivity Meter
- Pentype TDS Meter
- Pentype pH meter
- Pentype ORP meter
- Pen type conductivity TDS sali
- Pentype Free Chlorine Meter
- Dual channels TDS Meter for Dr
- Handheld Refractometer
- Laboratory
- Laboratory Conductivity meter
- Laboratory Conductivity Meter
- Laboratory Conductivity and DO
- Laboratory pH meter
- Laboratory pH meter -precise M
- Laboratory pH and Conductivity
- Laboratory pH and Conductivity
- Laboratory pH and DO meter MP5
- Laboratory Dissolved Oxygen me
- Laboratory Turbidity Meter
- Laboratory Fluoride Ion Meter
- Laboratory Sodium Meter
- Laboratory BOD analyzer (diffe
- Laboratory COD Ammonia Nitroge
- Laboratory Calcium Ion Meter M
- Laboratory chroma meter CLR-3
- Laboratory Electrode
- Stirrer
- Accessories
- Aquarium
LDC (Insertion type Magnetic Flowmeter)
AddTime:2016-12-03 11:22:53 Views: 0

Insertion type Magnetic Flowmeter LDC series
Widely used in water, sewage, acid, alkali and other conductive liquid with conductivity higher than 5us / cm
Measuring media: conductive liquid
Measuring range: 127-254340m³ / h
Output signal: 4-20mA; RS485; HART protocol; MODBUS protocol
Accuracy class: 0.5 ~ 10m / s: ± 1.5% FS; 0.1 ~ 0.5m / s: ± 2.0% FS
Medium temperature: -20 ℃ ~ / + 130 ℃
Explosion levels: ExdIIBT6
Protection class: IP65 (Integrate) IP68 (split)
Product Overview
LDC plug-in electromagnetic flowmeter is developed on the basis of pipeline electromagnetic flowmeter on a new type of flow meter, it reserves the pipeline electromagnetic flowmeter basis of merit, for the pipeline electromagnetic flowmeter in pipeline installation difficulties, costs and large defects, according to the magnetic M.Niculae (NIKURADS) principle, electromagnetically energized by measuring the average flow velocity of the fluid, whereby the volume of fluid flow. Especially the use of hot tapping, under pressure after mounting technology, plug-in electromagnetic flowmeter can be installed without stopping the water can also be mounted on a cast iron pipes, cement pipes. The successful development of plug-in electromagnetic flowmeter for detecting fluid flow to provide a new means.
Product Features
Plug-in electromagnetic flowmeter Official Road traffic detection, installation is simple, do not stop, on-site classes Tapping, has the absolute advantage and installation price advantage;
For water, sewage, acid, alkali and other conductive liquid flow rate detection 5us / cm or more, the change does not affect the change in conductivity performance, highly complex changes to adapt to the fluid. Particularly suitable for measuring the flow of drainage channels;
Flowmeter no mechanical moving parts, the converter optimized design, compact, easy to install, converters and sensors are interchangeable, you can freely change the measuring range (0.5m / s ~ 10m / s);
The detected flow only to the depth of insertion, so that meter wide versatility and interchangeable. One model can be applied to a variety of fluid measurement requirements pipeline;
It can be connected to any standard secondary instrument;
4 ~ 20mA current output;
You can set the pulse output;
RS485 interface, HART communication protocol, MODBUS protocol;
Automatic range switching function. When the flow meter range, the range can be switched automatically to ensure accurate measurement of full scale;
Negative flow calculation function. User selectable forward or reverse metering metering (default is forward measurement);
Upper and lower alarm. Users can set upper and lower limits as required instantaneous flow when the flow exceeds the upper or lower limit value of the alarm buzzer or relay output (user selectable);
ATC alarm. In operation, when the inner tube empty tube flow meter, flow rate is zero, the upper right corner of the display alarm;
Power protection, operational results and parameters set by the user and then the meter after power is not lost, EEPROM set parameters can be saved and accumulated value;
Low-cut function. Users can set the display panel or the lower limit voltage flow, which cut little interference signal;
Instrument "auto-zero" principle, eliminate electrochemical signal interference, auto-zero;
Converters and sensors with a variety of installation and degree of protection, there are IP68 suitable for diving installation.
Technical Parameters
Pipe Diameter | 300-3000mm |
Flow speed range | 0.1~10m/s |
Accuracy | 0.5~10m/s:±1.5%FS;0.1~0.5m/s:±2.0%FS |
0.1~10m/s:±2.5%FS(FS means 40%~-100% full scale flow) | |
Conductivity | > 5µs/cm |
Straight pipe | Front 5DN, rear 3DN |
Media Temperature | -20℃~/+130℃ |
Ambient temperature | -20℃~/+60℃ |
Pressure | 1.6MPa |
Protection level | IP65(Integrate) IP68(Split) |
Electrode material | SS316L |
Output Signal | 4-20mA;RS485;HART protocol; MODBUS protocol |
Sensor Material | Stainless Steel |
Working Power | 220VAC,tolerant of 15% or24VDC,ripple≤5% |
Power | 6.5W |
Presure | ≤1.6MPa |
0.5 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | |
300 | 127 | 254 | 509 | 763 | 1017 | 1272 | 1526 | 1780 | 2035 | 2289 | 2545 |
350 | 173 | 346 | 692 | 1039 | 1385 | 1731 | 2077 | 2423 | 2769 | 3116 | 3464 |
400 | 226 | 452 | 904 | 1356 | 1809 | 2261 | 2713 | 3165 | 3617 | 4069 | 4523 |
450 | 286 | 572 | 1145 | 1717 | 2289 | 2861 | 3434 | 4006 | 4578 | 5150 | 5725 |
500 | 353 | 707 | 1413 | 2120 | 2826 | 3533 | 4239 | 4946 | 5652 | 6359 | 7069 |
600 | 509 | 1017 | 2035 | 3052 | 4069 | 5087 | 6104 | 7122 | 8139 | 9156 | 10180 |
700 | 692 | 1385 | 2769 | 4154 | 5539 | 6924 | 8308 | 9693 | 11078 | 12463 | 13847 |
800 | 904 | 1809 | 3617 | 5426 | 7235 | 9043 | 10852 | 12660 | 14469 | 16278 | 18086 |
900 | 1145 | 2289 | 4578 | 6867 | 9156 | 11445 | 13734 | 16023 | 18312 | 20602 | 22891 |
1000 | 1413 | 2826 | 5652 | 8478 | 11304 | 14130 | 16956 | 19782 | 22608 | 25434 | 28260 |
1200 | 2035 | 4069 | 8139 | 12208 | 16278 | 20347 | 24417 | 28486 | 32556 | 36625 | 40694 |
1400 | 2769 | 5539 | 11078 | 16617 | 22156 | 27695 | 33234 | 38773 | 44312 | 49851 | 55390 |
1600 | 3617 | 7235 | 14469 | 21704 | 28938 | 36173 | 43407 | 50642 | 57876 | 65111 | 72346 |
1800 | 4578 | 9156 | 18312 | 27469 | 36625 | 45781 | 54937 | 64094 | 73250 | 82406 | 91562 |
2000 | 5652 | 11304 | 22608 | 33912 | 45216 | 56520 | 67824 | 79128 | 90432 | 101736 | 113010 |
2200 | 6839 | 13678 | 27356 | 41034 | 54711 | 68389 | 82067 | 95745 | 109423 | 123101 | 136778 |
2400 | 8139 | 16278 | 32556 | 48833 | 65111 | 81389 | 97667 | 113944 | 130222 | 146500 | 162778 |
2600 | 9552 | 19104 | 38208 | 57311 | 76415 | 95519 | 114623 | 133726 | 152830 | 171934 | 191038 |
2800 | 11078 | 22156 | 44312 | 66468 | 88623 | 110779 | 132935 | 155091 | 177247 | 199403 | 221558 |
3000 | 12717 | 25434 | 50868 | 76302 | 101736 | 127170 | 152604 | 178038 | 203772 | 228906 | 254340 |