Product
- Industrial
- Conductivity Meter
- Resistivity Meter
- pH Meter
- Reverse Osmosis Controller
- Flow Meter
- Dissolved Oxygen Meter
- Free chlorine analyzer
- Turbidity Meter
- TSS Meter
- COD
- Fluorion Analyzer
- Sodium Meter
- Silicate Meter
- Hydrazine Analyzer
- Multiparameter analyzer
- Management system
- Transmitter
- Sensor
- Control Panel
- Installation Accessories
- Plastic Electric Box
- water treatment materials
- One-stop Purchase Materials
- Handheld
- Portable Conductivity Meter
- Portable pH meter
- Portable pH and conductivity a
- Portable pH and conductivity m
- Portable pH and dissolved oxyg
- Portable pH ORP conductivity D
- Portable ORP meter
- Portable Dissolved Oxygen mete
- Portable conductivity and DO m
- Portable Free Chlorine meter
- Portable Acid Meter SX7120
- Portable Acid-Alkali Meter SX7
- Portable Hardness Meter YD300
- Portable turbidity meter
- Portable Thermometer
- Portable Tachometer -laser typ
- Portable aquaculture multipara
- Portable COD
- Pentype Conductivity Meter
- Pentype TDS Meter
- Pentype pH meter
- Pentype ORP meter
- Pen type conductivity TDS sali
- Pentype Free Chlorine Meter
- Dual channels TDS Meter for Dr
- Handheld Refractometer
- Laboratory
- Laboratory Conductivity meter
- Laboratory Conductivity Meter
- Laboratory Conductivity and DO
- Laboratory pH meter
- Laboratory pH meter -precise M
- Laboratory pH and Conductivity
- Laboratory pH and Conductivity
- Laboratory pH and DO meter MP5
- Laboratory Dissolved Oxygen me
- Laboratory Turbidity Meter
- Laboratory Fluoride Ion Meter
- Laboratory Sodium Meter
- Laboratory BOD analyzer (diffe
- Laboratory COD Ammonia Nitroge
- Laboratory Calcium Ion Meter M
- Laboratory chroma meter CLR-3
- Laboratory Electrode
- Stirrer
- Accessories
- Aquarium
PHS-8660
AddTime:2016-12-08 19:30:06 Views: 0

Applies Institute, schools, businesses and other laboratory analysis to accurately measure the pH of the aqueous solution.
Characteristics:
1, professional, high-performance embedded smart chip of 0.001 laboratory pH meter;
2, automatic calibration and automatic (manual) temperature compensation;
3, instrument internal memory buffer, the national standards and other parameters;
4, the standard three composite containing pH sensor temperature;
5, the end of the sensor response function is determined, the instrument automatically determine the response of the end state of the sensor readings are more accurate;
6, the instrument has a self-diagnostic function, easy operator use to solve problems;
7, automatically determine the properties of the composite pH sensor;
8, ion measurements, matching the corresponding ion measurement sensors can be used to measure ion aqueous solution;
9, measuring crank bracket universal standard crank sensor holder, easier operational use;
10, with the domestic first time complete GLP functions;
11, 1024 with a GLP-compliant set of measurement data storage function;
12, with timing and automatic storage function;
13, with RS232 communication interface.
Technical Parameters:
Instrument Type: pHS-8660
Measuring range
pH: 0.00 ~ 14.00
ORP: -1999.9mV ~ + 1999.9mV
Temperature: (-5.0 ~ 105.0) ℃
Resolution
pH: 0.001
ORP: 0.1mV
Temperature: 0.1 ℃
Accuracy
pH: ≤0.05
ORP: ≤ ± 1% FS
Temperature: ± 0.3 ℃
Approximate Input impedance: 3 × 10 12Ω
Temperature compensation range: 0 ~ 100 ℃ (25 ℃ as compensated reference)
Storage capacity: 1024 Group
Stored content: measured value ID, the measured value, temperature value, ACT or MTC status, date of measurement, time of measurement
Power: DC 9V Power Adapter (AC 220V ± 10%)
Power consumption: <5W
Environmental requirements
Operating temperature: (5 ~ 40) ℃
Relative humidity: ≤85% RH
Storage environment
Temperature: (-20 ~ 60) ℃; Relative humidity: ≤85% RH (non-condensing)