Product
- Industrial
- Conductivity Meter
- Resistivity Meter
- pH Meter
- Reverse Osmosis Controller
- Flow Meter
- Dissolved Oxygen Meter
- Free chlorine analyzer
- Turbidity Meter
- TSS Meter
- COD
- Fluorion Analyzer
- Sodium Meter
- Silicate Meter
- Hydrazine Analyzer
- Multiparameter analyzer
- Management system
- Transmitter
- Sensor
- Control Panel
- Installation Accessories
- Plastic Electric Box
- water treatment materials
- One-stop Purchase Materials
- Handheld
- Portable Conductivity Meter
- Portable pH meter
- Portable pH and conductivity a
- Portable pH and conductivity m
- Portable pH and dissolved oxyg
- Portable pH ORP conductivity D
- Portable ORP meter
- Portable Dissolved Oxygen mete
- Portable conductivity and DO m
- Portable Free Chlorine meter
- Portable Acid Meter SX7120
- Portable Acid-Alkali Meter SX7
- Portable Hardness Meter YD300
- Portable turbidity meter
- Portable Thermometer
- Portable Tachometer -laser typ
- Portable aquaculture multipara
- Portable COD
- Pentype Conductivity Meter
- Pentype TDS Meter
- Pentype pH meter
- Pentype ORP meter
- Pen type conductivity TDS sali
- Pentype Free Chlorine Meter
- Dual channels TDS Meter for Dr
- Handheld Refractometer
- Laboratory
- Laboratory Conductivity meter
- Laboratory Conductivity Meter
- Laboratory Conductivity and DO
- Laboratory pH meter
- Laboratory pH meter -precise M
- Laboratory pH and Conductivity
- Laboratory pH and Conductivity
- Laboratory pH and DO meter MP5
- Laboratory Dissolved Oxygen me
- Laboratory Turbidity Meter
- Laboratory Fluoride Ion Meter
- Laboratory Sodium Meter
- Laboratory BOD analyzer (diffe
- Laboratory COD Ammonia Nitroge
- Laboratory Calcium Ion Meter M
- Laboratory chroma meter CLR-3
- Laboratory Electrode
- Stirrer
- Accessories
- Aquarium
PH ORP-2012
AddTime:2016-12-10 15:30:37 Views: 0

Product description::
Digital pH-ORP controller with large size LED display for easy reading.
High input impedance avoid measuring error.
Built in SLOPE and CAL. adjust knob, easy for single
point or two points pH calibration.
"PH ORP" control, the relay "PH" when measuring value is above the set point for pH.
And the relay "ORP" when measuring value is below the set point for ORP.
Model | PH-2012 | |
Measuring range | PH | 0.00~14.00PH |
ORP | -1999~1999mV | |
Accuracy | PH | ±0.1%+0.02PH |
ORP | ±5 mV | |
Resolution | PH | 0.01PH |
ORP | 1mV | |
Set Range | PH | 3.50~10.50PH |
ORP | -500~500mV | |
Environment | Temperature:0~50℃ Humidity<95℅ | |
Display | double 4 LED display reading | |
Power Supply | 220V±10℅ 50Hz±2℅ | |
Dimensions | 150mm×85mm×40mm |