Product
- Industrial
- Conductivity Meter
- Resistivity Meter
- pH Meter
- Reverse Osmosis Controller
- Flow Meter
- Dissolved Oxygen Meter
- Free chlorine analyzer
- Turbidity Meter
- TSS Meter
- COD
- Fluorion Analyzer
- Sodium Meter
- Silicate Meter
- Hydrazine Analyzer
- Multiparameter analyzer
- Management system
- Transmitter
- Sensor
- Control Panel
- Installation Accessories
- Plastic Electric Box
- water treatment materials
- One-stop Purchase Materials
- Handheld
- Portable Conductivity Meter
- Portable pH meter
- Portable pH and conductivity a
- Portable pH and conductivity m
- Portable pH and dissolved oxyg
- Portable pH ORP conductivity D
- Portable ORP meter
- Portable Dissolved Oxygen mete
- Portable conductivity and DO m
- Portable Free Chlorine meter
- Portable Acid Meter SX7120
- Portable Acid-Alkali Meter SX7
- Portable Hardness Meter YD300
- Portable turbidity meter
- Portable Thermometer
- Portable Tachometer -laser typ
- Portable aquaculture multipara
- Portable COD
- Pentype Conductivity Meter
- Pentype TDS Meter
- Pentype pH meter
- Pentype ORP meter
- Pen type conductivity TDS sali
- Pentype Free Chlorine Meter
- Dual channels TDS Meter for Dr
- Handheld Refractometer
- Laboratory
- Laboratory Conductivity meter
- Laboratory Conductivity Meter
- Laboratory Conductivity and DO
- Laboratory pH meter
- Laboratory pH meter -precise M
- Laboratory pH and Conductivity
- Laboratory pH and Conductivity
- Laboratory pH and DO meter MP5
- Laboratory Dissolved Oxygen me
- Laboratory Turbidity Meter
- Laboratory Fluoride Ion Meter
- Laboratory Sodium Meter
- Laboratory BOD analyzer (diffe
- Laboratory COD Ammonia Nitroge
- Laboratory Calcium Ion Meter M
- Laboratory chroma meter CLR-3
- Laboratory Electrode
- Stirrer
- Accessories
- Aquarium
PHG-2081D (Multi Channel)
AddTime:2016-12-02 13:46:02 Views: 0

Features
It can arbitrarily chosen dual channel to four channel pH meter. All the channels are mutually independent, non interfering, and most can be connected with four electrode pH at the same time. It is English LCD display, English menu operation.
Microcomputer: It adopts high-performance CPU chip, high-precision AD conversion technology and SMT |
technology to complete the multi-parameter measurement, temperature compensation and instrument |
self-checking, with high precision and good repeatability. |
25℃ Conversion: Nernst electrode slope temperature compensation, pure water and ultra-pure water with |
addition of ammonia converted at 25℃. |
Double high impedance input circuit: Low pH electrode resistance, the instrument has good stability, fast |
response, strong anti-interference . |
Solution grounding: This can eliminate all the disturbance of the ground circuit. |
Technical Parameters:
1. Measuring range: pH value: 0~14.00pH; division value: 0.01pH |
Temperature: 0~99.9℃; division value: 0.1℃ |
Electric potential value: ±1999mV; division value: 0.1mV |
2. Precision: pH value:±0.05pH: Temperature:±0.5℃(0~60.0℃) |
3.Range for automatic temperature compensation: 0~99.9℃, with 25℃ as the reference temperature |
4. Water sample tested: 0~99.9℃,0.6Mpa |
5. Automatic temperature compensation error of the electronic unit: ±0 03pH |
6. Repeatability error of the electronic unit: ±0.02pH |
7. Stability: ±0.02pH/24h |
8. Double high impedance input, input impedance: ≥1012Ω |
9. Isolated current output: 4~20mA(load <750Ω) |
10. Protection grade: IP65 |
11. Working conditions: ambient temperature: 0~60℃; relative humidity <85% |
12.According to the measurement medium optional pH electrode |
13. Weight: 0.8kg |
14. Power supply: AC 220V±22V, 50Hz±1Hz;DC24V(optional) |
15. Overall dimension: 146 (length) x 146 (width) x 108 (depth) mm; |
dimension of the hole: 138 x 138mm |
16. Instrument channel number: Two to four channels can be selected, each channel is independent each other. |
Please specified channel number when ordering, according to the two channel configuration without specified. |
Each channel data be measured at the same time, with the screen display, without switching display |
17. Secondary meter installation type: opening type/hanging type/framing type/pipe type |
18. Electrode installation type: circulating type/ submergence type/flange type/ pipe type |