Handheld Refractometer

AddTime:2016-12-09 23:54:46          Views: 0

\   \


Refractometer is a precision optical instrument that specifically measure the concentration of the solution, easy to use. ATC is added with a temperature compensation system. Portable refractometer is by direct reading the scale for measuring the concentration of various solutions specially designed, such as: fruit juice, soft drinks, honey, salt, water, cleaning fluid, battery fluid, and industrial antifreeze solution and the like. At the same time, easier to use.
Measurement Principle:
Based on the ratio of the refractive index of the amount of sugar in sugar-containing solutions and design principles of concentration refractometer it can be used for direct determination of the sugar content of sugar solution. As long as the detection prism mirror Add 2-3 drops of test solution can be. Sugar refractometer for rapid determination of solubility, density wine sugary solution; you can also measure the refractive index of other non-sugar solubility or by conversion, is sugar, food, beverage, wine, agricultural research, textile and mining machinery, etc. of the necessary instrumentation. Product looks beautiful, precision, durability, the full range, affordable.
Refraction theory of refraction meter
If you place a pencil in a glass of water, the top will appear curved. Then the top if you put sugar in a cup and try the same experiment, the pencil should appear even more bent, and an example of this phenomenon is the refractive index.
Refractometer result of new optical systems into a practical use. The test solution is measured by converting the corresponding relationship between the refractive index of the solution to its solubility solubility when increasing the density of the material (for example, when the sugar in water solubility when dissolved substance increases), its refractive index increases proportionately primers.
1. refractometer prism hold a higher refractive index than the sample solution theory; test solution to measure the refractive index of solubility or through conversion.
2. In the case of weak test solution, the test solution is higher refractive index than the prism, so the angle of refraction is relatively large (see A. In the following chart).
3. In the case of relatively strong test solution, the test solution is lower than the refractive index of the prism, so the angle of refraction is relatively small (see chart below at B.).


 
Hand Held Refractometer - Brix
    The RHB series is developed for working with sugar related liquids (fruit juices, soft drinks, wine), help monitor and control sugar concentrations in foods and beverages. Whether users are checking the "ripeness" of fruit in the field, verifying product quality after harvesting, or controlling concentrations during processing and packaging, refractometers provide critical information to ensure product quality. But, is also commonly used for controlling the concentration of various industrial fluids cutting lubricants and flux rinsing compounds. Full ranges of measurement is available.
Model Range Resolution Accuracy Remark
RHB-10 Brix:  0-10% Brix:  0.1% Brix:  ±0.10% Without Atc
RHB-10ATC Brix:  0-10% Brix:  0.1% Brix:  ±0.10% Atc
RHB-20 Brix:  0-20% Brix:  0.1% Brix:  ±0.10% Without Atc
RHB-20ATC Brix:  0-20% Brix:  0.1% Brix:  ±0.10% Atc
RHB-32 Brix:  0-32% Brix:  0.2% Brix:  ±0.20% Without Atc
RHB-32ATC Brix:  0-32% Brix:  0.2% Brix:  ±0.20% Atc
RHB-55 Brix:  0-55% Brix:  1% Brix:  ±1% Without Atc
RHB-92 Brix:  58-92% Brix:  0.2% Brix:  ±0.2% Without Atc
RHB-62 Brix:  28-62% Brix:  0.2% Brix:  ±0.20% Without Atc
RHB-62ATC Brix:  28-62% Brix:  0.2% Brix:  ±0.20% ATC
RHB-82 Brix:  45-82% Brix:  0.5% Brix:  ±0.5% Without Atc
RHB-82ATC Brix:  45-82% Brix:  0.5% Brix:  ±0.5%  Atc
RHB-90 Brix: 58-90%
Baume: 38-43Be'
water: 12-27% 
Brix: 0.5%
Baume: 0.5Be'
water: 1% 
Brix: ±0.5%
Baume: ±0.5Be'
water: ±1% 
Without Atc
RHB-90ATC Brix: 58-90%
Baume: 38-43Be'
water: 12-27% 
Brix: 0.5%
Baume: 0.5Be'
water: 1% 
Brix: ±0.5%
Baume: ±0.5Be'
water: ±1% 
Atc 
RHB0-80 Brix:  0-80% Brix:  1% Brix:  ±1% Without Atc
Hand Held Refractometer - Salinity
    The RHS series are designed for testing the concentration of salt water and brine. Provides a direct reading of the specific gravity and concentration (Parts Per Thousand) of salt in water. It provides reliable refractive index and salinity readings of total dissolved solids of aqueous solutions. It is used for quality control in research and clinical laboratories. It can be used to check and maintain stock solutions and dilutions. In the food industry, it is especially effective in the preparation of frozen vegetables, fruits, seafood and ocean by products. The Salinity Refractometer is also used in oceanography and seawater studies for determining soil quality. The model having ATC (Automatic Temperature Compensation) is ideal for field use.
Model Range Resolution Accuracy Remark
RHS-10 Salinity: 0-100‰
Specific gravity:
1.000-1.070  
Salinity: 1‰
Specific gravity:
0.001 
Salinity: ±1‰
Specific gravity:
±0.001
Without Atc
RHS-10ATC Salinity: 0-100‰
Specific gravity:
1.000-1.070  
Salinity: 1‰
Specific gravity:
0.001 
Salinity: ±1‰
Specific gravity:
±0.001
Atc
RHS-28 Salinity:  0-28% Salinity:  0.2% Salinity:  ±0.2% Without Atc
RHS-28ATC Salinity:  0-28% Salinity:  0.2% Salinity:  ±0.2% Atc
RHS-10a Salinity: 0-100‰
Brix:  0-10%
Specific gravity:
1.000-1.070  
Salinity: 1‰
Brix:  0.2%
Specific gravity:
0.001
Salinity: ±1‰
Brix:  ±0.2%
Specific gravity:
±0.001
Without Atc
RHS-10b Salinity: 0-100‰
Brix:  0-10%
Specific gravity:
1.000-1.070  
Salinity: 1‰
Brix:  0.2%
Specific gravity:
0.002
Salinity: ±1‰
Brix:  ±0.2%
Specific gravity:
±0.002
Without Atc
RHS-28a Salinity: 0-28%
Brix:  0-32%
Salinity: 0.2%
Brix:  0.2%
Salinity: ±0.2%
Brix:  ±0.2%
Without Atc
Hand Held Refractometer - Clinical Protein
     The RHC series are designed for clinical usage and intended for both Veterinary and Human Being. This unit provides veterinarians and Human Being with quick and accurate indication of vital fluids' levels. Its triple scale reads Total Serum Protein, Refractive Index and Urine Specific Gravity.
Model Range Resolution Accuracy Remark
RHC-200 Serum Protein: 
0-12g/dl
Specific Gravity:
1.000-1.050sg
Refractive Index:
1.330RI-1.360RI  
Serum Protein:
0.2g/dl
Specific Gravity:
0.005sg
Refractive Index:
0.0005RI  
Serum Protein:
±0.2g/dl
Specific Gravity:
±0.005sg
Refractive Index:
±0.0005RI
Without Atc
RHC-200ATC Serum Protein: 
0-12g/dl
Specific Gravity:
1.000-1.050sg
Refractive Index:
1.330RI-1.360RI 
Serum Protein:
0.2g/dl
Specific Gravity:
0.005sg
Refractive Index:
0.0005RI 
Serum Protein:
±0.2g/dl
Specific Gravity:
±0.005sg
Refractive Index:
±0.0005RI  
Atc
Hand Held Refractometer - Battery/Antifreeze/Cleaning Fluid
    The RHA series are designed for measuring the concentration of the battery fluids. the freezing point of antifreeze liquid and windshield cleaning fluid. With the indication of the percentage you may know at which temperature the fluid will be frozen for both propylene glycol and ethylene glycol. It can also be used for checking the strength of electrolyte solution battery.
Model Range Resolution Accuracy Remark
RHA-100 Ethylene Glycol: 
-84° F- 32° F
Propylene Glycol:
-60° F- 32°  F
Battery: 
1.100-1.400sg 
Ethylene Glycol: 
5° F
Propylene Glycol: 
5° F
Battery: 
0.01sg 
Ethylene Glycol: 
±5° F
Propylene Glycol: 
±5° F
Battery: 
±0.01sg 
Without Atc
RHA-100ATC Ethylene Glycol: 
-84° F-32° F
Propylene Glycol:
-60° F-32°  F
Battery: 
1.100-1.400sg 
Ethylene Glycol: 
5° F
Propylene Glycol:
5° F
Battery: 
0.01sg 
Ethylene Glycol: 
±5° F
Propylene Glycol: 
±5° F
Battery: 
±0.01sg 
ATC
RHA-200 Ethylene Glycol:
-60°C-0°C
Propylene Glycol:
-50°C-0°C
Battery:
1.100-1.400sg 
Ethylene Glycol:
5°C
Propylene Glycol: 
5°C
Battery: 
0.01sg 
Ethylene Glycol: 
±5°C
Propylene Glycol: 
±5°C
Battery: 
±0.01sg 
Without Atc
RHA-200ATC Ethylene Glycol:
-60°C-0°C
Propylene Glycol:
-50°C-0°C
Battery: 
1.100-1.400sg 
Ethylene Glycol:
5°C
Propylene Glycol:
5°C
Battery:
0.01sg 
Ethylene Glycol:
±5°C
Propylene Glycol:
±5°C
Battery:
±0.01sg 
ATC
RHA-300F Ethylene Glycol:
-60°F-32°F
Propylene Glycol:
-50°F-32°F
Battery: 
1.15-1.30sg 
Ethylene Glycol: 
10°F
Propylene Glycol: 
10°F
Battery: 
0.01sg 
Ethylene Glycol: 
±10°F
Propylene Glycol: 
±10°F
Battery: 
±0.01sg 
Without Atc
RHA-303 Ethylene Glycol:
-70°C-0°C
Propylene Glycol:
-60°C-0°C
Battery:
1.10-1.40sg  
Ethylene Glycol:
5°C
Propylene Glycol: 
5°C
Battery: 
0.01sg 
Ethylene Glycol: 
±5°C
Propylene Glycol: 
±5°C
Battery: 
±0.01sg 
Without Atc
RHA-403C Ethylene Glycol: 
-50°C-0°C
Propylene Glycol: 
-50°C-0°C
Battery: 
1.15-1.30sg
Cleaner: 
-40°C-0°C 
Ethylene Glycol: 
5°C
Propylene Glycol: 
5°C
Battery: 
0.01sg
Cleaner: 
5°C 
Ethylene Glycol: 
±5°C
Propylene Glycol: 
±5°C
Battery: 
±0.01sg
Cleaner: 
±5°C 
Without Atc
RHA-503C Battery: 
1.100-1.400sg
Ethylene Glycol: 
-50°C-0°C
Propylene Glycol: 
-50°C-0°C
Cleaner: 
-40°C-0°C 
Battery: 
0.01sg
Ethylene Glycol:
5°C
Propylene Glycol: 
5°C
Cleaner: 
5°C 
Battery: 
±0.01sg
Ethylene Glycol: 
±5°C
Propylene Glycol: 
±5°C
Cleaner: 
±5°C 
Without Atc
RHA-501 Battery:
1.10sg-1.40sg
Ethylene Glycol:
-60°F-32°F
Ethylene Glycol:
-50°C-0°C
Propylene Glycol:
-50°C-0°C
Propylene Glycol:
-50°F-32°F 
Battery: 
0.01sg
Ethylene Glycol: 
10°F
Ethylene Glycol: 
5°C
Propylene Glycol: 
5°C
Propylene Glycol: 
10°F 
Battery: 
±0.01sg
Ethylene Glycol: 
±10°F
Ethylene Glycol: 
±5°C
Propylene Glycol: 
±5°C
Propylene Glycol: 
±10°F 
Without Atc
Hand Held Refractometer - Alcohol,Wine
    The RHW series are developed for working with alcohol or sugar related wines and concentration of alcohol. It can measure the alcohol concentration in wines or water solution. And it also is developed for measuring the sugar in the grapes, that helps the manufacturer to decide the best time to manufacture the grape wine.
Model Range Resolution Accuracy Remark
RHW-80 w/w: 0-80% w/w: 1% w/w: ±1% Without ATC
RHW-25 alcohol:  0-25% alcohol:  0.2% alcohol:  ±0.20%  Without Atc 
RHW-25a alcohol:  0-25%
Baume:    0-20
alcohol:  0.2%
Baume:    0.2
alcohol:  ±0.2%
Baume:    ±0.2
Without Atc
RHW-25a ATC alcohol:  0-25%
Baume:    0-20
alcohol:  0.2%
Baume:    0.2
alcohol:  ±0.2%
Baume:    ±0.2
Atc
RHW-25ATC alcohol:  0-25% alcohol:  0.2% alcohol:  ±0.20%  Atc
RHW-25b alcohol:  0-25%
Brix:     0-40%
alcohol:  0.2%
Brix:     0.2%
alcohol:  ±0.2%
Brix:     ±0.2%
Without Atc
RHW-25bATC alcohol:  0-25%
Brix:     0-40%
alcohol:  0.2%
Brix:     0.2%
alcohol:  ±0.2%
Brix:     ±0.2%
ATC
Hand Held Refractometer - °OE Tester
    The °OE Testers are ideal for concentrated fruit juice and canned foods that use a sugar infusion.It has three scales: Oechsle(Oe°), Brix(%Sucrose) and KMW
Model Range Resolution Accuracy Remark
RHBS-32 Brix: 0-32%
Oechsle: 0-140°Oe
KMW: 0-25°Babo  
Brix: 0.2%
Oechsle: 1.0°Oe
KMW: 0.2° 
Brix: ±0.2%
Oechsle: ±1.0°Oe
KMW: ±0.2° 
Without ATC
RHBS-32a Brix: 0-32%
Oechsle: 30-140°Oe
Brix: 0.2%
Oechsle: 1.0°Oe
Brix: ±0.2%
Oechsle: ±1.0°Oe
Without ATC
RHBS-32aATC Brix: 0-32%
Oechsle: 30-140°Oe
Brix: 0.2%
Oechsle: 1.0°Oe
Brix: ±0.2%
Oechsle: ±1.0°Oe
ATC
RHBS-32ATC Brix: 0-32%
Oechsle: 0-140°Oe
KMW: 0-25°Babo 
Brix: 0.2%
Oechsle: 1.0°Oe
KMW: 0.2° 
Brix: ±0.2%
Oechsle: ±1.0°Oe
KMW: ±0.2° 
ATC
RHBS-44 Brix: 0-44%
Oechsle: 0-190°Oe
KMW: 0-40°Babo 
Brix: 0.5%
Oechsle: 2.0°Oe
KMW: 0.5° 
Brix: ±0.5%
Oechsle: ±2.0°Oe
KMW: ±0.5° 
Without Atc
 

Ask for Price?

* Model

* I am from (Country) My Company Name is

My Industry / Business is

* We are a

* I Have Used This Product Before or Not?

I am Interested in Order Pieces This Time.

* My Contact Email is

My Name is

My other contact information

Contact us

Address:5-2-1203, Ximeihuajie, Shijiazhuang, 050000 China

Tel/Fax: +86 311 8523 6569

Mob: +86 139 3384 0735

Skype: createc528

Email: info@hbbossen.com

close ->