Product
- Industrial
- Conductivity Meter
- Resistivity Meter
- pH Meter
- Reverse Osmosis Controller
- Flow Meter
- Dissolved Oxygen Meter
- Free chlorine analyzer
- Turbidity Meter
- TSS Meter
- COD
- Fluorion Analyzer
- Sodium Meter
- Silicate Meter
- Hydrazine Analyzer
- Multiparameter analyzer
- Management system
- Transmitter
- Sensor
- Control Panel
- Installation Accessories
- Plastic Electric Box
- water treatment materials
- One-stop Purchase Materials
- Handheld
- Portable Conductivity Meter
- Portable pH meter
- Portable pH and conductivity a
- Portable pH and conductivity m
- Portable pH and dissolved oxyg
- Portable pH ORP conductivity D
- Portable ORP meter
- Portable Dissolved Oxygen mete
- Portable conductivity and DO m
- Portable Free Chlorine meter
- Portable Acid Meter SX7120
- Portable Acid-Alkali Meter SX7
- Portable Hardness Meter YD300
- Portable turbidity meter
- Portable Thermometer
- Portable Tachometer -laser typ
- Portable aquaculture multipara
- Portable COD
- Pentype Conductivity Meter
- Pentype TDS Meter
- Pentype pH meter
- Pentype ORP meter
- Pen type conductivity TDS sali
- Pentype Free Chlorine Meter
- Dual channels TDS Meter for Dr
- Handheld Refractometer
- Laboratory
- Laboratory Conductivity meter
- Laboratory Conductivity Meter
- Laboratory Conductivity and DO
- Laboratory pH meter
- Laboratory pH meter -precise M
- Laboratory pH and Conductivity
- Laboratory pH and Conductivity
- Laboratory pH and DO meter MP5
- Laboratory Dissolved Oxygen me
- Laboratory Turbidity Meter
- Laboratory Fluoride Ion Meter
- Laboratory Sodium Meter
- Laboratory BOD analyzer (diffe
- Laboratory COD Ammonia Nitroge
- Laboratory Calcium Ion Meter M
- Laboratory chroma meter CLR-3
- Laboratory Electrode
- Stirrer
- Accessories
- Aquarium
DCS-8600 (Multi-parameters)-DCS-8600
AddTime:2016-12-03 13:55:23 Views: 0

Conductivity can, pH, ORP, chlorine, dissolved oxygen, turbidity, temperature, flow, level and many other water quality parameters configuration can also be configured for other physical parameters;
1. water monitoring, environmental monitoring stations, municipal water treatment process, municipal pipe network water quality supervision, rural water monitoring;
2. For the circulating cooling water, swimming pool water operation and management, industrial water recycling, industrial aquaculture.
1, the integration of multi-parameter instrument system integration platform, the measurement parameter type can transform module attribute flexible combination;
2, the conductivity can, pH, ORP, chlorine, dissolved oxygen, turbidity, temperature, flow, level and many other water quality parameters configuration can also be configured for other physical parameters;
3, flexible parameters to add or change, may actually need to be task-oriented or random combination of customized assembly according to;
4, each sensor are supported by artificial field calibration, you can also use standard solution reserve timed automatic calibration;
5, you can use high-speed, high-fidelity data bus acquisition, can also use the traditional 4 ~ 20mA signal acquisition;
6, with touch-screen human-machine interface for the operating core measurement parameters can be 4-16 with screen display;
7, massive storage space can be measured parameters and historical data recorded history curves playback, both the U disk data file export capabilities;
8, you can use RS485 communication, GPRS, WIFI, Zigbee wireless transmission access to the Internet for remote monitoring and fault diagnosis;
9, access to external information, data or other independent measurement units scattered through this system for data integration, information processing package;
10, series measurement / control system integration, adding PLC or other control modules, actuators constructed based on overall water quality parameters measurement and control system integration.
project
Multi-parameter water quality analysis instruments online
Remark
touch screen
7-inch man-machine interface
Measuring range
pH 1 ~ 14 0.01pH (Resolution)
Optional
ORP -2000 ~ 2000mV 1mV
Optional
Conductivity (0.5 ~ 2000) μS / cm 0.01μS / cm
Optional
Inductive Conductivity 0.5mS / cm ~ 2000mS / cm 0.01μS / cm
Optional
Resistivity of 0.00 ~ 18.25 MΩ · cm 0.01MΩ * cm
Optional
flow
Instantaneous flow: (0 ~ 2000) m3 / h
Cumulative flow: (0 ~ 99999999) m3
Flow rate: (0 ~ 5) m / s 0.001 m3 / h (minimum)
Optional
DO 0.0 ~ 20.00mg / L 0.01 mg / L
Optional
Chlorine 0.01 ~ 2.00mg / L (ppm) 0.01mg / L
Optional
Turbidity (0 ~ 100) NTU or (0 ~ 4000) NTU 0.001NTU
Optional
Supply voltage: AC 220V ± 10%, 50Hz
working environment
Temperature: (0 ~ 50) ℃, relative humidity: ≤95% RH (non-condensing)
Communication interface: RS485 MODBUS RTU communication protocol
Ethernet Interface: 100M network interface, can be used for data transmission
Optional
Output Interface: USB, can be used for data dump
Data storage: 5000 groups
Insulation resistance: more than 20MΩ
Degree of protection: IP43
Installation: Floor-mounted enclosure