Product
- Industrial
- Conductivity Meter
- Resistivity Meter
- pH Meter
- Reverse Osmosis Controller
- Flow Meter
- Dissolved Oxygen Meter
- Free chlorine analyzer
- Turbidity Meter
- TSS Meter
- COD
- Fluorion Analyzer
- Sodium Meter
- Silicate Meter
- Hydrazine Analyzer
- Multiparameter analyzer
- Management system
- Transmitter
- Sensor
- Control Panel
- Installation Accessories
- Plastic Electric Box
- water treatment materials
- One-stop Purchase Materials
- Handheld
- Portable Conductivity Meter
- Portable pH meter
- Portable pH and conductivity a
- Portable pH and conductivity m
- Portable pH and dissolved oxyg
- Portable pH ORP conductivity D
- Portable ORP meter
- Portable Dissolved Oxygen mete
- Portable conductivity and DO m
- Portable Free Chlorine meter
- Portable Acid Meter SX7120
- Portable Acid-Alkali Meter SX7
- Portable Hardness Meter YD300
- Portable turbidity meter
- Portable Thermometer
- Portable Tachometer -laser typ
- Portable aquaculture multipara
- Portable COD
- Pentype Conductivity Meter
- Pentype TDS Meter
- Pentype pH meter
- Pentype ORP meter
- Pen type conductivity TDS sali
- Pentype Free Chlorine Meter
- Dual channels TDS Meter for Dr
- Handheld Refractometer
- Laboratory
- Laboratory Conductivity meter
- Laboratory Conductivity Meter
- Laboratory Conductivity and DO
- Laboratory pH meter
- Laboratory pH meter -precise M
- Laboratory pH and Conductivity
- Laboratory pH and Conductivity
- Laboratory pH and DO meter MP5
- Laboratory Dissolved Oxygen me
- Laboratory Turbidity Meter
- Laboratory Fluoride Ion Meter
- Laboratory Sodium Meter
- Laboratory BOD analyzer (diffe
- Laboratory COD Ammonia Nitroge
- Laboratory Calcium Ion Meter M
- Laboratory chroma meter CLR-3
- Laboratory Electrode
- Stirrer
- Accessories
- Aquarium
pH Sensor-Composite Purewater PH sensor PH8022
AddTime:2016-12-02 17:26:02 Views: 0

1. The polymer filling makes the reference junction potential very stable.
2. The diffusion potential is very stable; large-area diaphragm surrounds the glass diaphragm bubbles, so that the distance from the reference diaphragm to the glass diaphragm is near and constant; the ions diffused from diaphragm and the glass electrode quickly form a complete measurement circuit to respond quickly, so that the diffusion potential is not easy to be affected by the outside flow rate and is thus very stable!
3. As the diaphragm adopts the polymer filling and there is small and stable amount of overflowing electrolyte, it shall not pollute the measured pure water.
Therefore, the above-mentioned features of the composite electrode make it ideal for measuring PH value of high-purity water!
Model No.: PH8022 |
Measuring range: 0-14pH |
Temperature range:0-85℃ |
Compressive strength:0.6MPa |
Slope: ≥96% |
Zero point potential: E0=7PH±0.3 |
Internal impedance: ≤250 MΩ (25℃) |
Profile: 3-in-1Electrode (Integrating the temperature compensation and the solution grounding) |
Installation size: Upper and Lower 3/4NPT Pipe Thread |
Connection: Low-noise cable goes out directly. |
Application: Measurement of all kinds of pure water and high-purity water. |
Features of PH Electrode
● It adopts the world-class solid dielectric and a large area of PCE liquid for junction, difficult to block and |
Convenient maintenance. |
● Long-distance reference diffusion channel greatly extends the service life of electrodes in the harsh |
environment. |
● It adopts PPS/PC casing and the upper and lower 3/4NPT pipe thread, so it is easy for installation and there is |
no need of the jacket, thus saving the installation cost. |
● The electrode adopts the high-quality low-noise cable, which makes the signal output length more than 40 |
meters free of interference. |
● There is no need for additional dielectric and there is a little amount of maintenance. |
● High measurement accuracy, fast echoing and good repeatability. |
● Reference electrode with silver ions Ag/AgCL |
● Proper operation shall make service life longer. |
● It can be installed in the reaction tank or pipe laterally or vertically. |
● The electrode can be replaced by a similar electrode made by any other country. |